Calculation wizard for the height of a fixed
guard for applications with high risk acc. to
DIN EN 13857

Application:
Please select distance C of the safety guard applicable to your use and
height a of the point of operation by clicking on the common field in the table with the mouse. The result is the desired height of the safety guard.

Height of hazard area c
b
Height of construction a, b
b to be protected
1 000 1 200 1 400 1 600 1 800 2 000 2 200 2 400 2 500 2 700
Horizontal safety distance to hazard area c
2 700 0 0 0 0 0 0 0 0 0 0
2 600 900 800 700 600 600 500 400 300 100 0
2 400 1 100 1 000 900 800 700 600 400 300 100 0
2 200 1 300 1 200 1 000 900 800 600 400 300 0 0
2 000 1 400 1 300 1 100 900 800 600 400 0 0 0
1 800 1 500 1 400 1 100 900 800 600 0 0 0 0
1 600 1 500 1 400 1 100 900 800 500 0 0 0 0
1 400 1 500 1 400 1 100 900 800 0 0 0 0 0
1 200 1 500 1 400 1 100 900 700 0 0 0 0 0
1 000 1 500 1 400 1 000 800 0 0 0 0 0 0
800 1 500 1 300 900 600 0 0 0 0 0 0
600 1 400 1 300 800 0 0 0 0 0 0 0
400 1 400 1 200 400 0 0 0 0 0 0 0
200 1 200 900 0 0 0 0 0 0 0 0
0 1 100 500 0 0 0 0 0 0 0 0

Calucalation wizard for the height of a fixed guard for applications with low risk acc. to DIN EN 13857

Obstacles with a height under 1000 mm are not included since they do not satisfactorily limit the movement.