S = 1600 * T + C
T is the total of response time of the AOPD, safety interface and the stop time of the machine.
C = 1200 - 0,4 * H; Cmin = 850 mm
H is the Height of the protected field above ref. plane;
Hmin =15 * (d - 50 mm); Hmax = 1000 mm;
Height > 300 mm there is a risk of crawling beneath!
To calculate the required d when the height of the protected field is known:
d = H / 15 + 50 mm
d is the detection capability of the AOPD in mm.
Condition:
50 ≤ d ≤ 116 mm