| For the calculation of the minimum depth of the protective field, in accordance with the directive DIN EN 61496-3 and the norm DIN EN 999, the following relations apply: |
|
S = K * T + C
T = TAOPDDR + TMach. + (Tafter. * Lafter.)
C = 1200 - 0,4 * H
 |
Here:
| S |
is the safety clearance - i.e. the distance from the danger zone to the point or line of detection. |
| K |
= 1600 mm/s, the speed of approach of a person or of a person's bodily parts. |
| T |
After-run time of the entire system, response time of the laser scanner TAOPDDR, response time of the machine Tmach. and after-run time of the machine Tafter.Taking into account wear and tear on the brake
Lafter = 1.1; otherwise Lafter = 1 |
| C |
= 1200 mm - 0,4 * H Safety related constant to take into account penetration of the danger zone before the protective device is triggered.
CMin = 850 mm; |
| H |
Height of the level of measurement value registration from the point of reference.
HMin = 15 * (d - 50) = 300
HMax = 1000; |
| d |
Resolution of the scanner (70 mm breadth of protective field) |
|
| The depth of the protective field, in relation to the direct distance between the danger zone and the detection point or detection line, is calculated on the basis of the following formula:
Here the following terms are used:
|
Here the following terms are used:
ST = S + ZGes + ZAU
ZGes = ZSM + ZREFL
Maximum range of protective field:

SBDIFF = GBDIFF + S + ZGes
|
Here:
| ST |
Depth of protective field, distance from the danger zone to the detection point or detection line, including the additions |
| ZGes |
Sum of the system-specific and application-related additions to the protective field |
| ZSM |
Measurement error by the scanner, with dust algorithm enabled
ZSM = 98, if SMAX > 3500 mm
ZSM = 81, if SMAX < 3500 mm |
| ZREFL |
Addition to take reflectors into account, if Reflektoren, if yes ZREFL = 100 |
| ZAU |
Addition for the undercut (at the front) |
| GBDIFF |
Greatest breadth of danger zone |
| SBDIFF |
Greatest breadth of protective field |
| SMAX |
Maximum range of protective field |
|
 |
| Step 3: Check wether the scanner arrangements leaves any areas unmonitored. Safeguard any blind spots by implementing additional protective devices.
|
|
|